Ventilator Uses Any Mask, Even Vented Masks

Select the Mask Based on the Patient’s Needs, Not the Ventilator’s

Patient Comfort. Unmatched Leak Compensation. Optimal Synchrony.

One of the keys to successful NIV ventilation is a well-fitting mask. Not all faces are the same, so mask selection can be troublesome, especially when mask options are limited by the type of ventilator being used. Often, improperly fitted masks leak around the face making it harder for the patient to breathe and harder for the ventilator to meet the respiratory demands of the patient. To solve the problem, clinicians tighten the mask to alleviate the leak. While they may have made breathing easier for the patient, they’ve created a new problem of skin irritation and injuries, also affecting the patient’s comfort and increased expiratory resistance and CO2 rebreathing.

The Solution: The Panther 5N Dedicated NIV Ventilator

The Panther 5N was designed to provide the best patient experience from neonates to adults. The ventilator can be used with any mask, even vented masks, allowing the Respiratory Therapist to select a mask based on the patient’s needs and comfort rather than the ventilator’s requirements.

Even when high leaks are present, the Panther 5N’s proprietary algorithm, state-of-the-art proportional flow valve and powerful built-in dual-stage blower can handle the demand. The Panther’s innovative technology minimizes trigger delays and reliably detects weak or ineffective patient efforts. The ventilator immediately responds by delivering higher pressure, high flows and precise breaths to the patient, reducing their effort and enhancing their comfort.

The Panther 5N ventilator provides optimal synchrony, unmatched leak compensation and patient comfort, all keys to successful NIV.

Panther 5N

Panther 5N Ventilator Highlights

  • Maintains optimal synchrony in the presence of high leaks
  • Immediate delivery of very high flows on patient demand
  • HFOT and invasive ventilation capabilities
  • Use with a variety of circuits and masks, including vented masks
  • Independent of compressed air
  • No expensive maintenance needed
  • Intuitive, easy-to-use interface
  • Neonates to adults
  • Optimal solution to replace the Philips V60

Panther 5N Specifications and Capabilities

  • Screen size: 15″
  • High-performance touch screen for ease of control
  • NIV modes: PCV, S/T, AVAPS, CPAP
  • NIV terminology and modes: IPAP/EPAP
  • Invasive modes: A/C-PC, S/T, A/C-PRVC
  • Oximetry
  • Capnography
  • Integrated Nebulizer (Pneumatic and Aerogen)
  • Precise flow up to 340 LPM, delivering immediate trigger response
  • 200 LPM of leak compensation
  • Pressure delivery range: 100 cmH20
  • Tidal Volume range: 2 mL – 2500 mL
  • Adjustable PEEP max: 50 cmH2O

Contact us for a demonstration, evaluation or more information by completing the form on this page or calling 866-367-7221.

Contact Us Today!

Or give us a call, 866.367.7221